id,summary,reporter,owner,description,type,status,milestone,component,version,severity,resolution,keywords,cc 3374,"""Runtime parameters reference"" documentation lists incorrect parameter/environment variable names",David G. Kahane ,Gennadiy Rozental,"http://www.boost.org/doc/libs/1_39_0/libs/test/doc/html/utf/user-guide/runtime-config/reference.html Item detect_memory_leaks lists ""Command line argument name: build_info""; this should be ""detect memory_leaks"", and likely the list label should be changed to match. ""BOOST_TEST_DETECT_MEMORY_LEAK"" (singular) is correct for the environment variable. Item report_format lists ""Command line argument name: report""; this should be ""report_format"". Item report_level lists ""Environment variable name: BOOST_TEST_LOG_FORMAT"" and ""Command line argument name: log_format""; these should be ""BOOST_TEST_REPORT_LEVEL"" and ""report_level"" respectively.",Bugs,closed,Boost 1.59.0,test,Boost 1.39.0,Problem,fixed,,